LAQUAact PD110
Overview

Features
- Dual channel, switchable display
- Automatic pH calibration up to 5 points using NIST, USA, or custom pH buffers
- 0.01 pH resolution
- Offset and slope display
- Automatic / manual temperature compensation
- Temperature calibration function
- Measures dissolved oxygen (DO) concentration in mg/L and % saturation units
- 0.01 mg/L or 0.1% DO resolution
- Compensates salinity, temperature, and atmospheric pressure
- Up to 2 DO calibration points
- Auto log data
- Built-in memory can store up to 1000 data
- Auto-shut off (programmable: 1 to 30 minutes)
- Auto-Hold / Auto-Stable measurement
- Caibration alarm (programmable: 1 to 400 days)
- Built-in electrode holder allows 2 electrodes to be attached on both sides of the meter
- Large backlit LCD: 52mm x 64mm
- RS232C output for connecting the meter to compatible printer or computer
- IP67-rated case: waterproof (withstand 30 mins. immersion in 1m depth of water) and dustproof
- Powered by 2 x AAA (LR03) or Ni-MH rechargeable batteries or power adaptor
- Packaged in new molded carrying case
- 2 years meter warranty
Meter Kits Available
PD110-K
Package Details:
- LAQUAact PD110 Dual channel pH/ORP/DO/Temp handheld meter with built-in electrode holder and 2 x AAA batteries
- 9651-10D plastic-body, gel-filled pH electrode with integrated temperature sensor
- 9551-20D Galvanic DO probe with integrated temperature sensor, 2m cable
- 4.01, 7.00, 10.01 pH buffers (60ml each)
- Instruction manual
- Carrying case
PD110-KN
- Meter kit with 6.86 and 9.18 pH buffers (in place of 7.00 and 10.01 pH buffers)
Manufactured by HORIBA Advanced Techno
Specifications
Model | LAQUAact PD110 Dual Channel pH/ORP/DO/Temperature(°C) |
|---|---|
pH Range | -2.00 to 16.00 pH |
Resolution | 0.01 pH |
Accuracy | ± 0.01 pH |
Calibration Points | Up to 5 |
Buffer Options | USA / NIST / Custom |
ORP Range | ± 2000 mV |
Resolution | 1 mV |
Accuracy | ± 1mV or 0.2% of reading (Whichever is greater) |
DO Range | 0.00 to 20.00 mg/L / 0.0 to 200.0 % |
Resolution | 0.01 mg/L or 0.1 % |
Accuracy | ± 0.1 mg/L |
Salinity Compensation | 0.0 to 40.0 ppt |
Barometric Pressure Compensation | Yes |
Temperature Compensation | Yes |
Calibration Points | Up to 2 |
DO Probe | Galvanic with integrated temperature sensor |
Temperature Range | -30.0 to 130.0 °C |
Resolution | 0.1 °C |
Accuracy | ± 0.4 °C |
Calibration Option | Yes |
Memory Data | 1000 |
Auto Log Data | Yes |
Real-time Clock | Yes |
Date / Time Stamp | Yes |
Auto-Shut Off | Yes (Programmable: 1 to 30 minutes) |
Auto-Hold / Auto-Stable | Yes |
Offset / Slope Display | Yes (Independent acid and alkaline slopes depending on calibration) |
Calibration Alarm | Yes (Programmable: 1 to 400 days) |
Electrode Status | On screen display |
Diagnostic Messages | Yes |
Display | Custom Backlit LCD / Dual Channel / Switchable Display |
Inputs | 2 x BNC, 2 x phono, DC sockets |
Output | RS232C |
IP Rating | IP67, shock-resistant |
Power Requirements | 2 x AAA (LR03) or Ni-MH rechargeable batteries or power adaptor |
Battery Life | > 500 hours |
Downloads
HORIBA Offices
Asia & Oceania
Singapore
HORIBA Instruments (Singapore) Pte Ltd.
work
83 Science Park Drive, #02-02A,
The Curie 118258 Singapore
work
+65 6 908 9660
work
fax
+65 6 745 8155
laqua@horiba.com
Europe, Middle East & Africa
Northampton
HORIBA UK Limited
Northampton Office
work
Kyoto Close,Summerhouse Road,
Moulton Park
Northampton NN3 6FL UK
Moulton Park
work
+(44) 1604 542 600
work
fax
+(44) 1604 542 699
waterquality@horiba.com
![LAQUA [Water Quality Analyzer Website] - HORIBA LAQUA [Water Quality Analyzer Website] - HORIBA](fileadmin/templates/img/logo_print.gif)