Overview
Features
Determine water conductivity with as little as 0.12 mL of sample.
The conductivity of rain water is a trusted guide to determining atmospheric purity. In agriculture, measuring the conductivity of soil allows farmers and agronomists to determine optimum fertiliser usage and check the ‘health’ of soil after salt water damage. The LAQUAtwin meter makes conductivity testing simple, anywhere.
Applications include:
Fresh water testing (rain, rivers, lakes, hot springs); aquaria; soil testing for improved agriculture and analysis of salt water damage; analysis of surface cleanliness prior to coating; and improved paint adhesion.
Functions
- Salt/TDS Measurement
- Auto range change
- Temperature conversion(2%/℃ fixed)
- IP67 waterproof
- Auto hold
- Automatic power off(15 minutes)
Manufactured by HORIBA Advanced Techno
Specifications
MODEL | B-771 | ||||
Measurement principle | 2 AC bipolar | ||||
Minimum | 0.12mL or more | ||||
Measurement range | Conductivity:0 to 19.9mS/cm(0 to 1.99S/m) | ||||
Display range | 0 to 199mS/cm (0 to 19.9S/m)*1 | ||||
Range and Resolution | ①0 to 199 μS/cm : 1μS/cm | ||||
Calibration | Two-point*2 | ||||
Accuracy | ±2%F.S.±1digit (for each range)*3 | ||||
Functions | Salt/TDS Measurement・・Auto range change・Temperature conversion(2%/℃ fixed)・Waterproof*4・Auto hold・Automatic power off(15 minutes) | ||||
Display | Custom (monochrome) Digital LCD | ||||
Operating | 5 to 40˚C, 85% or less in relative humidity (no condensation) | ||||
Power | CR2032 batteries (x2) | ||||
Battery life | Approx. 400 hours in continuous use | ||||
Main Material | ABS epoxy | ||||
Dimensions | 164mm × 29mm × 20mm (excluding projections) / Approx. 45 g (meter only, without batteries) | ||||
Accessories included | 2 CR2032 batteries/1 Pipette/Instruction manual/Quick manual/Storage case/Standard solution(1.41mS/cm) (14mL)/Treatment reagent (14mL) | ||||
*1 When the measured value is out of the measurement range, the displayed value blinks. It should be used only as a guide.
*2 Selectable between one-point and two-point calibrations. High conductivity standard solution (12.9mS/cm) is sold separately.
*3 Repeatability in measurement of a standard solution after calibration using the same standard solution.①±5μS/cm (0 to 199 μS/cm )②±0.05mS/cm(0.20 to 1.99mS/cm)③±0.5mS/cm (2.0 to 19.9mS/cm)
*4 IP67:no failure when immersed in water at a depth of 1 meter for 30 minutes. But the product can not be used underwater.
Brochures
Downloads
![]()
The materials accessible from this website were current at the time of posting.
Please note that the material may differ from that provided with the product. ![]()