Overview
Features
- Automatic / manual conductivity calibration up to 4 points
- Adjustable reference temperature and temperature coefficient
- Selectable cell constant and measurement unit
- Automatic / manual temperature compensation
- Temperature calibration function
- Resistivity, total dissolved solids (TDS), and salinity conversions from conductivity
- Four TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl
- Two salinity calibration curves: NaCl, Seawater
- Auto log data
- Built-in memory can store up to 1000 data
- Auto shut-off (programmble: 1 to 30 minutes)
- Real-time clock and date / time stamping
- Auto-Hold / Auto-Stable measurement
- Large backlit LCD: 52mm x 64mm
- RS232C output for connecting the meter to a compatible printer or computer
- Powered by 2 x AAA batteries (LR03) or Ni-MH rechargeable batteries or power adaptor
- IP67-rated case: waterproof (withstand 30 mins. immersion in 1m depth of water) and dustproof
- Packaged in new molded carrying case
- 2 years meter warranty
Meter Kit Available
EC120-K
Package Details:
- LAQUAact EC120 EC/Res/TDS/Sal/Temp handheld meter with built-in electrode holder and 2 x AAA batteries
- 9382-10D plastic-body, titanium/platinum black conductivity probe (k=1.0) with integrated temperature sensor
- 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm conductivity standard solutions (60ml each)
- Instruction manual
- Carrying case
Manufactured by HORIBA Advanced Techno
Specifications
Model | LAQUAact EC120 EC/Res/TDS/Sal/Temp(°C) |
---|---|
Conductivity (EC) Range | 0.000 µS/cm to 20.00 mS/cm (k=0.1) 0.00 µS/cm to 200.0 mS/cm (k=1) 0.0 µS/cm to 2.000 S/cm (k=10) |
Resolution | 0.05% of full scale |
Accuracy | ± 0.6% of full scale; ± 1.5% of full scale > 18.0 mS/cm |
Reference Temperature | 15 to 30 °C (Adjustable) |
Temperature Coefficient | 0.00 to 10.00 % (Adjustable) |
Cell Constant | 0.1 / 1.0 / 10.0 (Selectable) |
Measurement Unit | μS/cm, mS/cm, S/m (Auto-ranging / Manual) |
Calibration Points | Up to 4 (Auto / Manual) |
TDS Range | 0.00 mg/L to 100 g/L (TDS factor=0.40 to 1.00) |
Resolution | 0.01 mg/L |
Accuracy | ± 0.1% of full scale |
Calibration Curves | EN27888 / 442 / Linear / NaCl |
Resistivity Range | 0.0 Ω•cm to 2.000 MΩ•cm (k=10) 0.000 kΩ•cm to 20.00 MΩ•cm (k=1) 0.00 kΩ•cm to 200.0 MΩ•cm (k=0.1) |
Resolution | 0.05% of full scale |
Accuracy | ± 0.6% of full scale; ± 1.5% of full scale > 1.80 MΩ•cm |
Salinity Range | 0.0 to 100.0 ppt / 0.00 to 10.00 % |
Resolution | 0.1 ppt / 0.01 % |
Accuracy | ± 0.2% of full scale |
Calibration Curves | NaCl / Seawater |
Temperature Range | -30.0 to 130.0 °C |
Resolution | 0.1 °C |
Accuracy | ± 0.4 °C |
Calibration Option | Yes |
Memory Data | 1000 |
Auto Log Data | Yes |
Real-time Clock | Yes |
Date / Time Stamp | Yes |
Auto-Shut Off | Yes (Programmable: 1 to 30 minutes) |
Auto-Hold / Auto-Stable | Yes |
Cell Constant Display | Yes |
Electrode Status | On screen display |
Diagnostic Messages | Yes |
Display | Custom Backlit LCD |
Inputs | BNC, phono, DC sockets |
Output | RS232C |
IP Rating | IP67, shock-resistant |
Power Requirements | 2 x AAA (LR03) or Ni-MH rechargeable batteries or power adaptor |
Battery Life | > 200 hours |
Downloads
HORIBA Offices
Asia & Oceania
Singapore
HORIBA Instruments (Singapore) Pte Ltd.
work
83 Science Park Drive, #02-02A,
The Curie 118258 Singapore
work
+65 6 908 9660
work
fax
+65 6 745 8155
laqua@horiba.com
Europe, Middle East & Africa
Northampton
HORIBA UK Limited
Northampton Office
work
Kyoto Close,Summerhouse Road,
Moulton Park
Northampton NN3 6FL UK
Moulton Park
work
+(44) 1604 542 600
work
fax
+(44) 1604 542 699
waterquality@horiba.com